Installing the VoIP Intercom
Intercom Setup
Operations Guide 930181E CyberData Corporation
7
2.2.2 Connecting a Device to the Auxiliary Relay
A normally open relay is provided to enable users to switch on an auxiliary device like a door
buzzer (see
Figure 2-4). The relay contacts are limited to 1 amp at 30VDC. The relay on time is
selectable through the web interface and is controlled by DTMF tones generated from the phone
being called. The DTMF tones are selectable from the web interface as well.
.
Note The three digit code for the auxiliary relay must be sent in conformance with RFC2833
DTMF generation.
Figure 2-5. Auxiliary Relay Wiring Diagram
Warning
Electrical Hazard: The VoIP Intercom enclosure is not rated for any AC voltages.
Warning
Electrical Hazard: This product should be installed by a licensed electrician
according to all local electrical and building codes.
Warning
Electrical Hazard: To prevent injury, this apparatus must be securely attached to
the floor/wall in accordance with the installation instructions.
1
2
3
4
+
-
DC
POWER SUPPLY
30VDC@1A
MAX.
IN
Switching Diode
High PIV UltraFast
Solid State
or
Mechanical
Relay
Controlled Device
Depending Upon
AC or DC rated
Output Contacts
Requirements
Power Source
AC or DC
Controlled Device
Such As
Electric Door Strike
or
Strobe Light
VoIP Intercom
()
OUT
5
6