Securing the Intercom
Operations Guide 930472A CyberData Corporation
67
A.5 Securing the Intercom
Use the four Security Torx screws to secure the Intercom. See Figure A-6.
Figure A-6. Securing the Intercom
Torx Key
Torx Screws
Faceplate &
PCB Assembly
2-Gang Box
2-Gang Box
Note: To mount the intercom, use methods
compliant with local electrical codes.
Caution
Equipment Hazard: Do not use an electric or power screwdriver to fasten the face
plate and PCB assembly to the gang box. To prevent over-torque damage to the
gasket, do not apply more than 10 inch-pounds force. Over-torquing will cause the
gasket to tear, risk moisture intrusion, and effectively void the manufacturer's
warranty.