RingCentral Office 11 To contact RingCentral, please visit www.ringcentral.com or call 1-800-574-5290.
Enter 4. 5060 in the Remote SIP Port field.
Enter 5. 5060 In the Local SIP Port field.
In the 6. Outbound Proxy field enter the value from your RC account labeled Outbound Proxy,
but do not include :5090. It should read sip.ringcentral.com.
Enter 7. 5090 in the Outbound Proxy Port field.
Enter the value from your RingCentral account labeled 8. User Name In the SIP User ID field.
Enter the value from your RingCentral account labeled 9. Authorization ID in the Authenticate ID field.
Enter the value from your RingCentral account labeled 10. Password in the Authenticate Password.
Make sure that the 11. Register with a SIP Server box is checked.
Leave all other settings at their default values.12.
Select 13. Save.
Select 14. Reboot.
Configuration completes once you reboot. You can now dial it using the extension or direct-dial number.
The speaker should answer and you can announce over the speaker.
Multicast Config – configures how the speaker should respond to multi-cast packets. This option is for using the
speaker as a member of a group using the Paging Server. If you are not using the paging server, leave this section
at defaults. If you are using the paging server, configure it as follows:
Check the box 1. Enable Multicast operation.
Note: The system has the capability to listen to multiple addresses at different priorities. For this
configuration overview, we assume you are only using one and will put it on priority 8.
In the row next to 2. 8, enter the multi-cast address you setup in your paging server into the address field.
By default it would be 224.224.224.224.
In the same row, enter the port you setup in your paging server into the port field. 3.
The default value is 9876.
Fill in the group name or leave it as default.4.
Click 5. Save.
Click 6. Reboot.
Audio Config – Allows you to customize audio tones played by the device in various situations. All options can be
left as default.
Clock Config – Not applicable for this device. The wall Intercom with clock will enable this section to set the
clock time.
Event Config – Allows you to have the device notify a logging event server of various activities. All options can be
left at default.
Autoprovisioning – Leave all options at default.
Update Firmware – Allows you to update the firmware on the device. See CyberData manual for updating firm-
ware if necessary.
Paging Server
Connect the paging server to your network. It does not need to be physically connected to the speaker.1.
On a computer connected to the same network, open a web browser and go to the address of the pag-2.
ing server. The default paging server address is 192.168.3.10.