Mounting the Intercom
Securing the Intercom
Operations Guide 930796L CyberData Corporation
96
A.7 Securing the Intercom
Figure A-12 illustrates how to secure the VoIP Outdoor Intercom with Torx screws.
Figure A-12. Securing the Intercom
Torx Key
Torx Screws
Faceplate &
PCB Assembly
2 Gang Box
Note: To mount the intercom, use methods
compliant with local electrical codes.
Caution
Equipment Hazard: Do not use an electric or power screwdriver to fasten the
face plate and PCB assembly to the gang box. To prevent over-torque damage to
the gasket, do not apply more than 10 inch-pounds force. Over-torquing will cause
the gasket to tear, risk moisture intrusion, and effectively void the manufacturer's
warranty.